We just put the pool in last summer (18'x52") with a Intex SWG CS8110) and a GAME SandPRO Model 8511 Filter. Therefore, there must be sufficient circulation and dissolution of the salt before the unit is switched on. Due to the low salt content in your pool water (sea water has on average 3.5%), you will not really feel, smell or taste any salt. First I tried the VR1 resistor CCW turn and that helped for a couple of hours. I had to be able to keep up and shock when I got a agle outbreak so I went Mod happy. I as well am having the exact same issue, plates are crystal clean, tons of salt in the pool but still after running for 15 mins get the low salt error so frustrating!! Intex Saltwater System Low Salt, Service Light, Error Code 91, Fix!!! We've never had as much trouble or used as much salt as we have this year. The storage cells are wearing parts that can be replaced regularly. I believe I tried everything on the Internet. hit that like button! One suggestion to try is a piece of plastic cut out of the front cover of an old Compact Disc case. (my brother put it together). Rinse it with clear water and reinstall it. Chewer25. i've ordered a new pump. How much Chlorine should I put in my Intex pool. No chlorine bubbles were being generated. Fix Your Intex Chlorinator Low Salt Code The Right Way!!! Create Device Mockups in Browser with DeviceMock, Creating A Local Server From A Public Address, Professional Gaming & Can Build A Career In It. Check the titanium and eco electrodes for dirt and deposits (lime, salt), clean them by soaking the cells in vinegar water. To do this, you need to unplug and unscrew the cell. Because remember it is now directly hooked to the main wire leading to the GFCI. The store will not work correctly in the case when cookies are disabled. shortly before that i replaced my pump with a pentair 1.5hp. connecting the system to pump and pool with 1 1 4 (32mm) connections hoses: the saltwater system features 1 1 2 (38mm) connections. Cycling the power switch does not bring the unit back to life. Thank you very much for the quick reply!! fustrated. The constant beeping drives me nuts! The salt water system requires an even salt concentration throughout the pool water. Lots and lots of salt has been added. This unit does not have a separate salinity sensor. Skip to the beginning of the images gallery, Adapter A, 32/38 mm mit 2" inner thread, Housing for electrolytic storage cell, ECO 8220/ECO 8220G, ECO electrode for ECO 8220/8230/8220G/20220/20230/6220/6230, Titanium electrode for ECO 8220G/8220/6220/6230, Swimming pool hose with screw fitting 2" internal thread, L= 100cm, Screw fitting for electrolytic storage cell housing, Screw fitting for electrolytic storage cell. If it is out of warranty or you just want to fix it, here is what I would try in order: I had the error 91. if i try to use the timer it would kick off with red service light. I will TRY TO POST video on youtube. so i need help please. What I did was unscrew the red and black wires from their "terminals" (I think thats what its called) coming from that "little black battery" to the "screw" (on the left side, where there are two black wires and one red and one white wire screwed). Intex Salt Water Generator Service Light Fix Cs15110. Any new postings here are unlikely to be seen or responded to by other members. If it is still under warranty and you have a receipt, call Intex for a replacement. please like, share & join my the intex saltwater system requires periodic maintenance. 5 Ways to Connect Wireless Headphones to TV, How to Use ES6 Template Literals in JavaScript, Introducing CSS New Font-Display Property, how to install django on windows 10 python step by step easy tutorial, create custom discord twitch emotes or sub badges for you by zegiav, creating virtual machines in vmware vcenter 4 x, how to make synthetic data synthetic data generation for machine learning, how to build an image picker using react native image crop picker logrocket blog, the spongebob squarepants anime complete edition official all openings ending creditless, how to use screen share with discord on iphone ipad, matte overlay transition pack for premiere pro sony vegas final cut pro davinci resolution, ultimate tech house and techno sample pack by loopmasters, materi bahasa inggris kelas x sma smk kurikulum 2013, p0328 how to bypass knock sensor nissan youtube, disewakan gudang siap pakai narogong raya km 12 5 bekasi, project surge stream overlays graphics for twitch and mixer streamers, react native basics copy to clipboard by spencer carli the react, Intex Saltwater Pump Red Service Light Fix, Intex Saltwater Chlorine Generator Service Light Fix Or Bypass Solution, Intex Cs8110 Salt Water System Short Breakdown (hd). Connecting the rectifier output directly to the cell bypasses the fuses and could destroy the transformer. Hello , This is an inactive thread. If I calculate right, this is the 5th season we've used it. what i found to fix the problem. Our Intex generator also gave up the ghost after four years of great service - we decided to watch the clearance sales to get another SWG so we are all ready next year. It is basically an ohmmeter. I have an older one I modded the heck out of new LEDs, flow sw directly contols cell relay ect. In the meanwhile, I decided to check online for solutions. Can anybody tell me why my cs7111 always has code 91. For the best experience on our site, be sure to turn on Javascript in your browser. The pictures shown are just for reference, the actual product may differ. What i found to fix the problem. please post the fix. We receive lots of comments about low salt codes that wont go away. You will need to time it on a manual alarm for the required time for chlorination (SEE: your manual for your pool size chlorination time). The sensor is calibrated to show the salinity that corresponds to the measured resistance. This starts to destroy any bacteria, algae and other organic material immediately. The reading in ohms should be approximately correct. Dad took a car battery charger to the outside and plugged it up. only a month, and the low salt button continues to light up. JavaScript is disabled. Check that all connection lines are open (gate valve, by-pass set). I AM NOT AN ELECTRICIAN!! You are using an out of date browser. Check the power supply in your socket, if necessary try another socket. Nobody seems to know or want to tell me why code 91 keeps coming back. Most visitors online was 3404 , on Jan 24 2020, Intellichlor Sensor Hack - 3 Wire Flow Switch. Any ideas? My unit is not toast I have done some diagnostics on my own( with no wiring diagrams since nobody seems to have them or share them) When the unit is in RUN mode the cell has 12 volts BUT when the code pops up with the low salt light the voltage drops to 0. than rehook it to the other square little "outletlike" thing closest to the fan (P6), left of the three blue squares. The girl at the pool store was really nice and t old me she didn't know anything about Intex products and I probably needed to contact Intex to find out for sure what the problem is, but she guessed the control panel is out. It has a flow sensor, which is easy to check, and bypass if needed. Weve had our brand new Intex Saltwater System with E.C.O. [quote="shorty74"] I will try to put video on youtube. Does anyone know how the CS8110 salt sensor works? All you will feel is clear, fresh, soft water. I got tired of messing with it and just bought a new one. I had the fiilter pump and the SWC on the same outlet. it is accordingly. Is it easier to re wire to get through the rest of the season (it is already the middle of August and we typically don't use our pool much after Labor Day) and purchase a new one next year?? On my third season of using my intex sand & saltwater pump, i started getting a red service light appearing and the pump turning off. Now add our free items to every order! Only the generator part works - no timer or nothing. In some cases, you may be able to remove this scale with the spray from a water hose, however its probably a better idea to perform the full cleaning outlined below. Clean the electrode of your pool's salt water system with vinegar or with a mild descaling agent that you dilute with water, depending on the product used. I get the code 91 after 2hrs of run time exactly. First soak the complete plastic part including the cells inside in vinegar for several hours. 2. take the saltwater system and its accessories open the catalog to page 8. To correct this problem, you must disassemble your unit and remove the generator cell. Plug the sensor firmly into the socket provided. The perfect option for above ground pools. I cleaned all censors, took out even the copper soaked in vinegar and rubbed gently with soft cloth, rinsed well and put back together. Check the titanium and eco-electrodes for dirt and deposits (lime, salt). the pool is filled and we put 200 pounds of 99.5% salt stuff in it after it desolved in big bucks first,then we pored it in the pool .anyways i need to know if im doing this wrong and i need a manual for the chlorine generator saltwater pool system pump.so i know if it is put together right. I'm not sure if mine is working or not after the rewiring. Can someone confirm that? Remove dirt from the housing of the storage cell. BTW, The 13.5V (no load) is before the unit shuts itself down (code 91) because I don't have it hooked up to the cell, it will output the voltage for maybe 15 seconds (until the unit errors) and then error and the voltage will drop to 0V with the error. to remove limescale from the electrode, as this could damage it. But if you just let the "88" stay on the machine will stay on along with the fan. We are a registered 501(c)3 non-profit that is funded by user donations. Perhaps the problem is in the salt sensor rather than with the plates? One problem that users have found with Intex saltwater chlorine generators is repetitive Low Salt Level errors even when salt levels in your water are adequate. I added six 40 lb bags of salt yesterday and am still getting the 91 code (low salt). The unit is a couple of years old and had been working during this season as well up until yesterday. An additional technique is to scrape or push the scale out from between the plates with a non-metal object. 3. place the saltwater system in line after the filter pump. From a minimum purchase value of EUR 40, - you can now order the following items for free. Easy!! I can't thank you enough for sharing this suggestion. For a better experience, please enable JavaScript in your browser before proceeding. The integrated electrolysis process reduces the mount of chlorine needed by up to 70%. Some people spoke of rewiring/bypassing wires in the generator, so I opened mine up and tried it. Assemble the above ground pool (agp) and its filter pump according to their installation instructions. We switched from cartridge pump to sand pump this year and we figured it was just that we were emptying more water when we vacuumed. So I switched electrical outlets and it did not solve my problem.