Price $3.45. Maintains a user-selectable amount of . It recovers, recycles, evacuates, leak tests and recharges R-134a vehicle systems quickly and accurately. Recover, recycle, evacuate, leak-test and recharge R-134a with improved 98.5 percent efficiency - unmatched by any competitor. AC1234-6 was the first commercially available machine to fully meet the SAE's requirement for recovering, recycling and recharging vehicle A/C systems that use the new R1234YF refrigerant. Vacuum Pump 3. No stopping to fill the internal tank during service, or before service. No stopping to fill the internal tank during service, or before service. Vacuum Pump Oil Fill 9. (Flushing adapters - not included) Automatic Air Purge: Eliminates damaging air without monitoring gauges or opening valves. Product Code: RA19798. The machine stops when the designated amount of refrigerant has been transferred to the ISV, or when the source tank is empty . Oil Injection Valves 2. The fully automatic function will recover, vacuum, leak test and charge on its own without the need to stand and monitor the machine. Automatic air purge removes the potential of air accumulating in the internal tank. internal tank is full and will not allow me to recover a system. Set-Up Instructions Diagram of Unit's Components External View 1. 34788NI recycles, evacuates, leak-tests and recharges R-134a with improved 98.5% recovery efficiency for standard vehicles and fully automatic function. This process takes 15-20 minutes. 8. Add To Cart. Automatic oil drain shows how much oil was removed from . Oil Drain Bottle 6. To clean contaminated ISV of Robinair 34700Z, open front lower panel, then slowly disconnect 3 hoses from ISV (Liquid, Air purge and Vapor). (3.6 kg) of refrigerant to ensure enough refrigerant is available for charging. Displays refrigerant use and monitors remaining filter life. But I don't see a way or procedure to . 3A Breaker (1.5A for 34801-2K) 7. The name of the new company was a combination of the names of two Kent-Moore executives, Robinette and Adair. Power Cord Receptacle 10. Press the STOP key to pause the process. Part #:ROB-AC1234-6. Oil Inject: Automatically inject oil back into the vehicle's A/C systems. 2# verify if there is high pressure in the ISV tank. Charge accuracy within +/- 1/2 oz. The new design features a larger graphical display, automatic features including leak testing, automatic refrigerant refill and oil drain/inject - putting A/C lubricant back into the . Qty: Description Prop65 Compressor 3/8 HP - 0.279kW. The kit contains one Quick Change filter-drier which can be used on both R-12 and R-134a stations, and one 16 ounce bottle of our Premium High Vacuum Pump Oil. The Robinair 34700Z is an automotive air-conditioning service machine. Automatic internal tank refill; no stopping to fill the internal tank during service, or before service. R-134a Hoses 3. Sight Glass 10. b. Posted to Tool & Equipment Forum on 8/26/2016 16 Replies. I know that I need a new filter, I think that a combo R12/R134 manifold gauge set should handle the fitting issues, the existing tank is empty (so I assume I can use it if the contents are properly marked, and of course a vacuum is . A new tank comes with a dry nitrogen charge of 5 to 10 psi to keep it clean and dry during shipment. This is a common problrm of Robinair 34700Z / 347002k & 347112k series machine.so don't worry just do the following :- 1# Verify the ISV tank is not overfilled.if full,remove refrigerant manually from tank. PRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. The tank is . Press STOP again to exit, or . specifically the type that hardens could be causing internal problems with the O-rings getting damaged. (23 kg) refillable tank, 1/2" ACME fittings. Robinair 34788NI and 34788NI-H machines recover, recycle, evacuate, leak-test and recharge R-134a with improved 98.5% efficiency - unmatched by any competitor. OVERFILLING OF THE TANK MAY CAUSE VIOLENT EXPLOSION AND POSSIBLE INJURY OR DEATH. Fits the internal face of the quickseal fitting on 134A hoses for recovery equipment, gauge set hoses and tank fill hoses with 1/2" ACME fittings. Hose Holders 8. Always point lines and hoses away from you and anyone nearby. The unit stops when a sufficient amount of refrigerant has been transferred to the internal tank, or when the source tank is empty. the tank is empty,the machine will not come out of clearing in any mode.i connected a service gauge on the manifold block when entering recovery it pulls down to 20 psi and will go no lower,is the compressor failing,shouldnt it pull to 0 psi.if i close the tank valves with the unit recovering it never hits high pressure. i have an empty source tank can i transfer freon to . Robinair's No. Recovery Performance 95% at 70 to 75F (21 to 24C) within 30 minutes. Be aware if you can lose your oil while turning upside down unless you cap the port and exhaust. The recovery compressor is not a vacuum pump. Do not mix refrigerant types through a system or in the same container; mixing of refrigerants will I have model 34788 recovery machine. Quick Couplers 11. Robinair 17121 30 lb. Read full answer. Robinair 34788NI Premier R/R/R A/C Machine. Scale Assembly 5. . Calibration Check Press START when finished. RA19798 Robinair Internal Tank Assembly : Price $ 757.58. Add at least 8 lbs. Parts Breakdown PDF. Adjust Tank Fill Lvl When connected to a refrigerant source, the unit maintains a pre-set amount of refrigerant in the internal storage vessel (default is 15 lbs.). Place the unit tank inside the ring on the scale platform on the back of the . Robinair 34788ni Manual TM Recovery / Recycling Unit Combines Simple Operation with Superior Accuracy The Cool-Tech 700 recovers, recycles, evacuates and recharges R-134a quickly and accurately. Fully automatic operation program for service, walk away and return when complete. Hey all, After looking in the owners manual and contacting Robinair and our local AC machine repair rep, I'm still not sure what the problem is with our AC machine. Internal Tank Assembly Storage tank attached to, or inside of unit, used to store recovered and/or recycled refrigerant. The AC1234-6 was the first commercially available machine to fully meet the SAE's requirement for recovering, recycling and recharging vehicle A/C systems that use the new R1234YF refrigerant. 98.5% recovery efficiency. The new design features a large capacity, removable tank, and a liquid pump to tackle those larger A/C systems typically found in buses. The new and used coolant tanks are built into the interior of the unit; each holds 30 quarts. . Prop65. This new refrigerant can be transferred see more The machine has an internal tank that is used to hold refrigerant recovered and used to charge a vehicle's A/C system. Scales 4. Robinair introduces its next innovation, the 34788NI, featuring an industry leading 98.5% recovery efficiency for standard and hybrid vehicles and fully automatic function. Description. R-12 Hoses Robinair was founded in 1956 by the Kent-Moore Corporation of Warren, Michigan, to design and manufacture specialized tools for repairing appliances. We recommend purchasing the Robinair AC1234-6 recovery machine. i have an empty - Answered by a verified Auto Mechanic . 2001 Robinair, SPX Corporation HIGH LOW Diagram of Unit's Components Internal View 1. Automatic oil drain shows how much oil was removed from the system during service. I would like to permanently retrofit it for R134a use. 10 minute with an external vacuum pump. 15A Breaker (7.5A for 34801- 2K) 6. Do not overfill the internal storage vessel because overfilling may cause explosion and serious personal injury or death. Robinair introduces its next innovation, the . This machine cleans, replenishes and maintains automotive air conditioning systems. The new design features a larger graphical display, automatic features including leak testing, automatic refrigerant refill and oil drain/inject - putting A/C lubricant back into the . Automatic internal tank refill. I just acquired a used Robinair 17400 R12 Recovery/Recycling machine. Operation Fully Automatic. Robinair A/C Machine replacement parts including High / Low Side Couplers, Hoses, Filters, Tank Fill Adapters, Oil Bottles, Solenoids, Dust Covers and more. a. . Buy Robinair 34788NI-H Premier R-134A Refrigerant Recovery, . Description. 112364 Robinair O-Ring For R-134a Quick Seal Fittings (Each) 112364 Robinair O-Ring For R-134a Quick Seal Fittings (Each). Do not recover refrigerants into nonrefillable containers; use only type-approved refillable containers that have pressure relief valves. The unit includes a 6 cfm (142 l/m) Robinair high vacuum pump for fast thorough evacuation. Before 93 we used R-12 for our vehicles and now, as I write this article in 2018, there is a push to phase . The internal storage vessel (ISV) maximum fill of new refrigerant may be adjusted between 1.8 kg and 6.8 kg by using the keypad. Do not attempt to adapt the unit for another refrigerant. Replacement Low/High side coupler, Hoses, Wheels, Filters, Oil Bottle, Solenoid, Tank Fill Adapter etc. 3# Check Vacuum check valve and Vacuum solenoid (see attach picture for location of Vacuum check valve . Description. (13.6 kg) DOT. The AC1234-6 is a fully automatic ACS machine that comes with an integrated refrigerant identifier that samples the refrigerant in the vehicle's A/C system prior to recovery, is a highly accurate and reliable machine, and can service both standard and hybrid vehicle A/C systems. Robinair's No. Ever since 1993 R-134a has been the staple refrigerant for automotive applications. Charge accuracy within +/- 1/2 Oz. Premier R-134A Refrigerant Recovery, Recycling, and Recharging MachineRobinair introduces its next innovation, the 34788NI, featuring an industry leading 98.. The tank is empty when it machine ships new. 1/4 Color VGA display, large easy . My machine says high pressure unit disabled and. ROBINAIR ROB-34788NI-H Premier R-134A Ref. i have a 34788 the service tank was empty over the winter, . If this is it, go straight to the Robinair web site and you can order one for around $25. Robinair was founded in 1956 and is a manufacturer of HVAC-R (heating, ventilating, air conditioning and refrigeration) and mobile products for agricultural, construction and automotive markets. . Automatic Oil Drain: A display reminds you to empty the graduated container to show the amount of oil to replace. My robinair 347002k does not hold a vacuum. Robinair 34788 Parts in stock. Do not recover or charge refrigerants into non-refillable containers; use only federally authorized refillable containers. ROB-AC1234-4. Hose Holder 7. No stopping to fill the internal tank during service, or before service. 13. . . Robinair 34788NI and 34788NI-H machines recover, recycle, evacuate, leak-test and recharge R-134a with improved 98.5% efficiency - unmatched by any competitor. The Robinair 34888HD heavy-duty machine recovers, recycles, evacuates, leak-tests, and recharges R-134a with 98.5% efficiency in both small and large mobile air conditioning systems. Internal Manifold A Robinair exclusive, this block manifold contains all the solenoids that control refrigerant flow, reducing the possibility of leaking connections. Internal Storage Vessel 4. If those areas are fine I would contact Robinair direct and ask tech support. Automatic internal tank refill. Safety devices require the use of only authorized refillable refriger-ant tanks. after emptying the tank, if possible make vacuum for approx. This segment of the video shows you how to fill the Internal Storage Vessel (ISV) on the Robinair R1234yf. USE THE UNIT WITH EITHER R-134a OR R-12 REFRIGERANT. (23 kg) refillable tank, 1/4" fittings. R-134a is the most commonly used refrigerant for automotive applications rather it be your twenty year old Toyota Camry or your Kenworth T-200 semi-truck. No stopping to fill the internal tank during service, or before service. With the increasing popularity of air conditioning, both for homes and automobiles, Robinair soon moved into this growing market. To order parts, please phone your order to 1-800-822-5561 All service related questions should be directed to the Robinair Technical Assistance Line at 1-800-822-5561. Fully-Automatic Function: Program to recover, vacuum, leak test and charge without operating panel valves. Keep your recovery and recycling unit operating at peak efficiency with our convenient maintenance kit. Refer to the instruction manual for tank specifications and ordering information. Robinair 34788NI and 34788NI-H machines recover, recycle, evacuate, leak-test and recharge R-134a with improved 98.5% efficiency - unmatched by any competitor. Press the STOP key to pause the process. The AC1234-6 is a fully automatic ACS machine that comes . Fully automatic operation program for service, walk away and . The machine includes an integrated refrigerant identifier that samples the refrigerant in the vehicle's A/C system prior to recovery. i have model 34788 recovery machine. Robinair 34788NI and 34788NI-H machines recover, recycle, evacuate, leak-test and recharge R-134a with improved 98.5% efficiency - unmatched by any competitor. 17506 - 50 lb. Automatic Air Purge: Eliminates damaging Electric Vehicle: Capable of servicing high voltage electric air without monitoring gauges or opening valves. Do not recover refrigerants Press START / YES to begin filling the internal storage vessel. The new Robinair 34988NI Premium A/C Machine combines ease of use and superior accuracy. 98.5% recovery efficiency. Vacuum fill an empty system Unique Space-Saving Cabinet: The tank-within-a-tank design is completely self-contained to save space in today's crowded shops. Control Panel Assembly 2. Air Purge Control 8. During setup of the machine, you will need to have a tank of new refrigerant (this does not come with the machine). Internal Storage Vessel Refrigerant is recovered into and charged out of this vessel, which is permanently mounted to the electronic scale for continuing reliability. Built-in the new "sidewinder " cabinet, it combines proven technology with the latest in time-saving features. Charge accuracy within +/- 1/2 oz. This unit was the first commercially available recovery machine to meet the new SAE standards J2843 for a 1234yf recovery machine. Charging Cylinder 30 lb. Dimensions (H x W x D) 47 in x 29 in x 29 in (119 cm x 74 cm x 74 cm) Weight 215 lb. Price $1.25. Automatic internal tank refill. Might just be something simple but not obvious. 2# Verify if there is high pressure in the tank.Purge excess air from the tank manually. 10. . Overfilling can cause explosion resulting in personal injury or death. Features: A/C system flush: Flushes a vehicle's A/C system with refrigerant eliminating any residual oil or other liquid. If full, carefully remove refrigerant manually from ISV tank by pressing tank valve. 9. PRESSURIZED TANK CONTAINS LIQUID REFRIGERANT . Display reminds you to empty the graduated container to show the amount of oil to replace ; . Robinair Cool Tech 34788 'tank full'. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators . Automatic Dye Inject: Gives the user the ability to use the machine to inject UV dye into a . message "Tank Full" If the tank is full of the correct freon you may be able to use it as the source tank and use the empty tank as the fill tank. 2# Check small compression fitting hoses back side of both gauges (Low and High) for any lose. NOTE: New style tank with quickseal fittings. The unit is designed to recover, recycle, and recharge only R-134a refrigerant. 34788 also boasts the ability to add a printer, USB data sharing . External Storage Vessel (ESV) 9. . The AC1234-4 is a fully automatic ACS machine that meets or exceeds SAE J2927 and J2843 standards for 1234yf recovery. View and Download RobinAir AC1234-6 instruction manual online. Features and Benefits: Fully automatic operation - program for service, walk away and return when complete. (98 kg) Display Color, 7" Capacitive Touch Screen. The machine includes an integrated refrigerant identifier that samples the refrigerant in the vehicle's A/C system prior . This value may be adjusted up or down to suit the user's needs. The unit stops when a sufficient amount of refrigerant has been transferred to the internal tank, or when the source tank is empty. Refer to instructions outlined in the Maintenance section under Adjust Tank Fill Level. It says "tank full, remove refrigerant" on the display and will charge but refuses to . Please check 1# Both service hoses (Red and Blue) fittings to the machine for damage of any "O" ring. The unit is designed for recover- ing, recycling, and recharging either R-134a or R-12 refrigerant. The compressor pulls the A/C system to a partial vacuum only; use the unit's vacuum cycle to remove moisture from the A/C system. Open the tank valve and invert the tank. R-12 Empty Refrigerant Tank Details As long as there's been air conditioning, there's been Robinair, the global leader of automotive and HVAC/R air conditioning (A/C) refrigerant recovery, recycling and recharge tools, equipment and accessories. Michael on Mon June 07, 2004 9:49 PM . Like I mentioned before this unit comes with a refrigerant identifier built right in so you don't have to worry about buying one of those as well. Press STOP again to exit, or START to resume. pressurized tank contains liquid refrigerant. Automatic internal tank refill. Automatic refrigerant refill feature maintains a user-selectable amount of refrigerant in an internal vessel and signals when it's time to change supply tank, no monitoring required . Tank Filling. The new design features a larger graphical display, automatic features including leak testing, automatic refrigerant refill and oil drain. The new design features a larger graphical display, automatic features including leak testing, automatic refrigerant refill and oil drain/inject - putting A/C lubricant back . Oil Drain Setup Instructions 1 2 Diagram of Unit's Components Side View 3 A display reminds you to empty the graduated container to show the amount of oil to replace. Robinair 1234YF Recover, Recycle, and Recharge Machine. internal tank is full and will not allow me to recover a system. Do not overfill the internal storage vessel (ISV). The user must dedicate the unit to only one type of refrigerant. Always unplug the station from the power source before removing any of the shrouding or beginning any service work. Now unscrew ISV tank from machine and then fixed an adapter to Liquid port of the tank to allow all the contaminated refrigerant to go out from tank. After the vacuum is complete, press START to begin filling the internal storage vessel. Oil Injection Bottles 5. The AC1234-4 is a fully automatic ACS machine that meets or exceeds SAE J2927 and J2843 standards for 1234yf recovery. Do not attempt to adapt the unit for another refrigerant. Press START to begin filling the external storage vessel. Oil Inject: Less than 1% cross-contamination. New design features a larger graphical display, automatic features including leak testing, automatic refrigerant refill, and oil drain/inject - putting A/C lubricant . If your machine is one of the bellow Model:- Robinair 34700Z / 347002K & 347112K series. The unit stops when a sufficient amount of refrigerant has been transferred to the internal tank or when the source tank is empty. i have a robinair 34288 machine that shows high pressure on the low side guage and will not recover due to the high pressure reading,i manually cleared the low side hose and got the . Recovery, Recycling & Recharging Machine for Hybrid & Non-Hybrid features Fully-Automatic Function: Program to recover, vacuum, leak test and charge without operating panel valves Automatic Oil Drain: A display reminds you to empty the graduated container to replace oil A/C System Flush: Flushes vehicle's A/C system with refrigerant . 34750 - 50 lb. Purge the nitrogen charge on the R-12 (gray and yellow) tank by opening the GAS (vapor) valve on the tank. 6. This process takes 15-20 minutes. AC1234-4 is a highly accurate and reliable machine capable of servicing both standard and . you to empty the graduated container to show the amount of oil to replace. Description. Vent the pressure to the atmosphere; then close the valve. AC1234-6 Service R1234yf refrigerant vehicles with Robinair's SAE-standard AC1234-6 ACS machine The AC1234-6 was the first A/C machine in North America to fully meet SAE's requirement for recovering, recycling and 14. Turn the unit upside down and look where the motor connects to the pump. just do the following, with POWER SWITCH OFF: - 1# Open front panel cover and verify the ISV tank is not overfilled.