Verify the inlet and outlet valves on the 25700 unit are closed. DO NOT OVERFILL. USA. USA. Pockets of refrigerant in desiccant and, in system oil will continue to vaporize as the A/C. storage tank (the type of container in which new refrigerant is sold) to recover refrigerant. Close the high- and low-side coupler valves, and. Replace the filter screen, if necessary. If an extension cord is used, it must be 14 AWG minimum and as short as possible to reduce voltage drops. 28635 Mound Road The 25700 will perform at its peak when voltage entering the machine (while operating) is between 115V AC and 122V AC. Toggle DYE INJECT on or off. (6ea. but vacuum remains a choice for the operator. CAUTION DO NOT PRESSURE TEST OR LEAK TEST EQUIPMENT AND / OR VEHICLE AIR CONDITIONING SYSTEMS WITH COMPRESSED AIR. If the technician cannot read this manual, operating instructions and safety precautionsmust be read and discussed in the technicians native language. 11. Select MODE to toggle between high- or low-side, charge, or both. ), Universal A/C Dye - Four Replacement Cartridges, Universal A/C Dye - Six Replacement Cartridges. NEVER use a standard disposable 30 lb. The 25700 unit is built and shipped ready to service contaminated R1234yf systems. This varies somewhat with ambient temperature, 5. 4. Your email address will not be published. Shut-off SwitchThis unit has an internal, high-pressure, shut-off switch. Cylinders used in conjunction with this equipment must be permanently marked with 20 mm black print that says: CONTAMINATED REFRIGERANT DO NOT USE. The display shows an overview of all tests, selected. Toggle the power switch to the ON position. The machine displays a summary of actions. automatically programs the vacuum step of the recovery process. Storage TanksWARNING: A storage tank is full when it reaches 80% volume. If pressure is, If a leak test was programmed, and a leak is, perform needed repairs. The operator must be EPA 609 certified and familiar with air conditioning and refrigeration systems, refrigerants, and the dangers of pressurized components. 28635 Mound Road WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE. Once it is determined there is no danger, the valves may be opened fully. CAUTION Risk of injury. To ensure an accurate leak test, it is imperative, that a thorough recovery and evacuation of, the system is performed. WARNING: TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE. conditioning system, or select NEXT to continue. Verify a clean filter screen is installed behind the inlet fitting. Use only authorized refillable refrigerant tank (with float switch installed) that meets DOT specs 4BW or 4BA. During the recovery, process, cold spots can develop in the A/C, system. Robinair strongly recommends the use of 400 psi cylinders. Run the 25700 until the desired vacuum is achieved. WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. The product must be maintained and serviced as specified. This product is warranted to be free from defects in workmanship, materials and components for a period of one year from date of purchase. To remove refrigerant from the A/C system, use only equipment certified for the type of refrigerant being removed. Enter a charge. Contact with refrigerant may cause personal injury. plugged into it. PRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. Disconnect the 25700 from the power supply before performing maintenance. AVOID BREATHING A/C REFRIGERANT AND LUBRICANT VAPOR OR MIST. WARNING: A storage tank is full when it reaches 80% volume. MUST BE RECLAIMED or DESTROYED by an EPA authorized facility. Recovered mixtures may be flammable and can potentially be ignited causing personal injury or death.ONLY RECOVER CONTAMINATED REFRIGERANT WITH THIS MACHINE. If the weight entered is more than the refrigerant, available in the internal tank, the charge, function will not start. The user may choose to skip any step in the automatic operation during the, programming. for instructions to Manually Fill the ISV. When an. Monitor the inlet pressure gauge to determine the presence of any remaining refrigerant. Connect the high- and low-side service hoses to the A/C system; open the coupler valves on the hoses.2. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Due to liquid expansion, the tank could explode if filled to more than 80% volume, possibly causing personal injury and equipment amage. 2022 BOSCH AUTOMOTIVE SERVICE SOLUTIONS INC. 4 CFM Vacuum Pump 110-115V/220-250V (selectable), Robinair vacuum pumps flyer - US and international models, Vacuum pumps - International models comparison, Operating Instructions - English (Document # 116292), Operating Instructions - Spanish (Document # 116292), Operating Instructions - French (Document # 116292), Operating Instructions - German (Document # 116292), Assembly Instructions (Document # 112877), http://www.youtube.com/watch?v=HnfmeXpu984, Operating Instructions - English (Document # 556679), Operating Instructions - Spanish (Document # 556679), Operating Instructions - French (Document # 556679), Owners Manual 15115-15310-15510 Vacuum Pumps - Multilingual: English, Spanish, French #555562 Rev. The unit will automatically shut down when the storage tank reaches 80% capacity if the float cable is used correctly. Failure to use a filter screen will invalidate your warranty. Only use Robinair tank, p/n 17990, with this machine. Mixing of refrigerants will cause severe damage to the unit and the system being serviced.ALL REFRIGERANT RECOVERED WITH THIS MACHINE IS TO BE RECLAIMED OR DESTROYED. Refer to the Maintenance section of this manual to remove the hose and filter assembly and replace them with the appropriate components for the refrigerant being serviced. Type of TankUse only authorized, refillable, refrigerant storage tanks. If the operator cannot read this manual, operating instructions and safety precautions must be read and discussed in the operators native language. Keeping caps on the valves will guard against refrigerant leakage. Exposure may cause personal injury. Connect the hose (provided) from the inlet fitting of the unit to the contamination port of the R1234yf RRR cart (or low-side port of the system being serviced). Use an outlet that does not have other appliances (such as lights, machines, etc.) The shut-off switch automatically resets itself after the pressure drops below 320 psi.MaintenanceCAUTION : The 25700 is specifically designed to recover contaminated refrigerant from an R1234yf RRR (recover, recycle, recharge) cart or a contaminated vehicle. 34988 Recovery, Recycling, Recharging Unit. Warranty service claims are subject to factory inspection for product defects. This warranty is non-transferable. Select NEXT to begin clearing hoses. Keep all connections to the refrigeration system dry and clean. 13. 4BW or 4BA. 20122022, manualsdir.comAll rights reserved. The 25700 is built and shipped ready to service contaminated R1234yf systems. Wear correct protective equipment, including safety goggles and protective gloves. Wear correct protective equipment, including safety goggles and protective gloves. Lower supply voltages may result in difficulty starting under high head pressure, reduced performance, and/or motor overheating. Before performing a refrigerant recovery, inspect and clean the filter screen in the inlet fitting on the 25700 unit. Before operating or repairing the unit, read and follow the instructions and warnings in this manual. The manufacturer is the sole determiner of warranty coverage. 2022 BOSCH AUTOMOTIVE SERVICE SOLUTIONS INC. Do not use the unit in the vicinity of spilled or open containers of gasoline or other flammable substances. Do not use the 25700 unit without correctly attaching the float cable to a storage tank with an internal float switch. Select SAVE to, 8. automatic sequence, the unit will beep three, times and the control panel readout will pinpoint, remains paused until the user enters a decision, Before the unit begins evacuating the A/C, checks for any pressure in the system that, may damage the vacuum pump. on ROBINAIR Refrigerant Recovery Machine 25700 User Manual, ROBINAIR Refrigerant Recovery Machine 25700, AJAX 8706 KeyPad Wireless Touch Keyboard User Manual, Meizhou Hongfeng Arts Crafts 266285 BJ 57IN Snowman With Snowflakes Instruction Manual, AJAX 7661 StreetSiren Wireless Outdoor Siren User Manual, AJAX 17938 12V PSU for Hub/Hub Plus/ReX Power Supply Unit User Manual, AJAX 10306 Transmitter Wired to Wireless Detector Converter User Manual, ZERFUN G8 Pro Wireless Microphone System User Manual, Airrex Infrared Heater AH-200/300/800 User Manual, 2017 Toyota Camry Hybrid LE Fuse Box Diagrams, 2017 Mitsubishi Lancer 4WD Fuse Box Diagrams, Mitsubishi Lancer Passenger and Engine Fuse Box Diagram, Mira Honesty ERD Bar Valve and Fittings User Manual. (6 ea. Slowly open the liquid valve of the storage tank while watching hoses and connections for leaks. Owatonna, MN 55060Telephone: 800.327.5060Fax: 866.287.722www.robinair.com. prepares the machine for the next service. Any other use could result in the contamination of recovered refrigerants with hydrocarbons and/or leak sealants. Use this equipment in locations with mechanical ventilation that provides at least four air changes per hour. If the inlet gauge displays a vacuum for the entire 5 minutes, turn the inlet valve on the 25700 to the CLOSED position. Refrigerant recovered with this equipment cannot be recycled. Do not exceed the maximum psig rating of the storage tank. Selecting NO disables recovery. Robinair recommends the user clean the filter screen regularly for optimal unit performance. When a contaminated R134a system needs to be serviced, see the parts list and Maintenance sections in this manual to install the necessary components. Connect the float cable to the float switch connection on the storage tank. Slowly open the inlet valve on the unit. 12. This will indicate no refrigerant remains in the system being serviced. Exposure may irritate eyes, nose, and throat. Note: Selecting YES. automatic sequence despite the failed leak test. Note: Data. This. Press YES to continue. Beforeoperating the unit, read and follow the instructions and warnings in this manual. Damage will occur if moisture is allowed to enter the system. At a minimum, the 25700 requires the use of a 350 psi storage tank.StorageStore refrigerant tanks in a cool, dry place.LeakageSome storage tanks have valves that were not correctly seated when manufactured. G, http://www.youtube.com/watch?v=3qJf0aiS4o8, Refrigerant Recovery/Recycling for Multiple Refrigerants, Multi-refrigerant recover, recycle, recharge machine, 17800C Product Brochure (Document # 18-18), Parts List & Operating Instructions - English, Economy R-134A Recover, Recycle, Recharge Machine, AC Machine Comparison and Accessories Compatibility flyer, R-1234yf vs R-134a Robinair machine comparison, 80211VCI refrigerant capacity database activation instructions, Robinair 134a A/C Machine Comparison Chart (Document # 16-74), Operating Manual, Multi-Lingual (Document # 579580 REV C), https://www.youtube.com/watch?v=5geZqp25Zn0, Cool-Tech 34788 A/C Recover, Recycle, Recharge Machine - International Model, SDS high vacuum pump oil Document # 552184). Place the 25700 unit on a flat, level surface. Home ROBINAIR ROBINAIR Refrigerant Recovery Machine 25700 User Manual. Disconnect power before servicing the unit. This equipment should only be operated by certified personnel. The display reads, Refer to the Maintenance section of this manual. 14 AWG and as short as possible. 1-800-533-6127, Bosch Automotive Service Solutions, Inc. HIGH VOLTAGE ELECTRICITY INSIDE THE UNIT HAS A RISK OF ELECTRICAL SHOCK. Decide if the unit should collect pre-recovery diagnostics by selecting YES or NO. which may be interpreted by the unit as a leak. The automatic function allows a user to program an automatic recovery, vacuum, leak test, and /, or charge sequence. Normal wear items (seals, filters, etc.) Customer Service / Tech Support If the inlet gauge displays a pressure above atmospheric pressure, repeat Steps 211 until vacuum is achieved. If recovery was not selected, the amount of oil to, be injected may be entered while programming, 7. Customer Service / Tech Support If you must use an extension cord, the cord must be No. This unit is provided with an 80% capacity shut-off float cable. the charge cycle, and no entry will be necessary. Comment document.getElementById("comment").setAttribute("id","a6e88443dfcecf15df08cd820d6dc129");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. Proof of purchase must be supplied with the product when returned. Note: If the unit begins to knock, slowly throttle back (close) the inlet valve until the noise stops. WARNING: To prevent personal injury, do not exceed the rated working pressure of the storage tank. Contact with refrigerant may cause personal injury. are specifically excluded from this warranty unless found by the manufacturer to be defective. If yes, enter amount of oil to, Note: The amount of oil recovered during the, recovery cycle is automatically injected before. The following information is critical to achieving the best refrigerant recovery results. Select START to begin the automatic, 10.When the sequence is complete, the display shows, diagnostics from the vehicle, start the vehicle's air. Select AUTOMATIC.3. Momentarily cycle system compressor to move trapped refrigerant. ), Replacement Dye Cartridges, 3/4 oz. Completely evacuate the 25700 of any residual refrigerant, and purge it with dry nitrogen before putting it in storage for a long period of time. If accidental system discharge occurs, ventilate the work area before resuming service. If during the warranty evaluation it is determined that proper maintenance was not performed, or that the product has been used in any way other than the purpose for which it was designed, the manufacturer reserves the right to void the warranty. The technician must be familiar with air conditioning and refrigeration systems, refrigerants, and the dangers of pressurized components. Refrigerant recovery is the process of taking refrigerant out of a system and storing it in a tank. A total automatic sequence may take an hour to complete.Note: When a charge cycle in automatic mode is complete, the machine will not prompt to equalize, hoses; it will automatically compensate this amount of refrigerant.1. If system pressure rises above 435 psi, the unit shuts off. system temperature equalizes toward ambient. ValvesWARNING: To prevent personal injury, open service, and tank valves SLOWLY to allow rapid shutoff of gas flow if necessary. Liquid refrigerant left in the units condenser may expand, causing damage to components. ALLOW ONLY QUALIFIED PERSONNEL TO OPERATE AND REPAIR THIS UNIT. Any refrigerant recovered with this equipment is to be returned to an EPA-approved refrigerant reclamation facility that will process it appropriately as per AHRI700 standard or dispose of it. weight using the keypad, and select SAVE. Disconnect hoses using extreme caution. Interface Kit (includes compressor bracket, motor bracket, motor- compressor interface, coupler w/ hardware, spacers), Motor Kit (includes motor, relay, capacitor, hardware), Manifold Knob Kit (includes red and blue manifold knobs), Low-side Gauge Kit (includeslow-side gauge, lens), High-side Gauge Kit (includeshigh-side gauge, lens), Panel Kit (includes front and back panels), Inlet Fitting / Filter Screen Kit (For R1234yf only; includes inlet fitting, filter screen, o-ring) Filter Screen Replacement Kit (For R134a only; includes inlet fitting, filter screens, o-ring), Blue Low-side Recovery Hose Assembly (For R1234yf only) Blue Low-side Recovery Hose Assembly (For R134a only), Compressor Rebuild Kit (includes piston seals, valves, springs, o- rings), Valve Rebuild / Replacement Kit (includes inlet /outlet valves and springs, o-rings), R134a Conversion Kit (includes low-side recovery hose assembly and inlet fitting & filter). ALL HOSES MAY CONTAIN LIQUID REFRIGERANT UNDER PRESSURE. As this occurs, A/C system pressure increases. Decide if the unit should perform a leak test by, 6. Bosch Automotive Service Solutions Inc. Singing Machine SML2200 User Manual - Optimized PDF Singing Machine SML2200 User Manual - Original PDF, Hisense Washing Machine User Manual - Download [optimized] Hisense Washing Machine User Manual - Download, Candy Washing Machine User Manual - Optimized PDF Candy Washing Machine User Manual - Original PDF, Smai Ski Machine User Manual - Optimized PDF Smai Ski Machine User Manual - Original PDF. If the product fails, it will be repaired or replaced at the option of the manufacturer. Empty refrigerant from the unit into a storage cylinder. The 25700 refrigerant recovery machine is capable of recovering either contaminated R1234yf or R134a systems. For specific instructions and information on the identification and recovery of such refrigerant within the R1234yf RRR cart, refer to the user manual supplied with that machine. remove the service hoses from the A/C system. Warren, MI 48092 Disconnect hoses using extreme caution. DO NOT OVERFILL. CAUTION: Used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage. may be printed from the Recover Diagnostics screen. Some mixtures of air and refrigerant have been shown to be combustible at elevated pressures. Additional health and safety information may be obtained from refrigerant and lubricant manufacturers. 9. Warren, MI 48092 The 25700 also includes the hose and connections to service contaminated R134a systems. The next step would be to set vacuum time. Use only Robinair tank p/n 17990 with this machine. Do not overfill storage tank without using provided float cable and float switch. The 25700 unit is shipped with a filter screen installed behind the inlet fitting. The warranty applies to products in normal use only, as described in this operating manual. Decide if the unit should perform a recovery by selecting YES or NO. All hoses may contain liquid refrigerant under pressure. Working PressureStorage tanks are designed for different working pressures. Overfilling or use of an unauthorized storage tank could result in serious injury or death. Due to liquid expansion, the tank could explode if filled to more than 80% volume, possibly causing personal injury and equipment damage. Ensure the correct inlet fitting and filter is used for the type of refrigerant being serviced. Isolate large amounts of refrigerant and close valves after use, so if a leak should develop anywhere in the system, the refrigerant will not escape to the atmosphere. Note: Charge mode after injecting, oil allows only a high-side charge. These mixtures, if ignited, may cause personal injury or property damage.DO NOT MIX REFRIGERANT TYPES THROUGH A SYSTEM OR IN THE SAME CONTAINER. Federal regulations require refrigerants to be transported only in containers meeting DOT specs. Decide if the unit should perform a charge by, selecting YES or NO. FiltersCAUTION: Filters prevent contamination from entering the unit, which reduces the risk of damage to the unit and the system being serviced. All warranty claims must be made within the warranty period. TO REDUCE THE RISK OF FIRE, avoid the use of an extension cord because the cord may overheat. 1-800-533-6127, Bosch Automotive Service Solutions, Inc. D, Owners Manual 15150-15800 Vacuum Pumps - Multilingual: English, Spanish, French #522683 Rev. 1. To avoid overfilling, use the included float cable in conjunction with Robinair tank p/n 17990 when recovering contaminated refrigerant with this machine. Do not use an extension cord unless needed. Slowly and carefully remove the inlet hose from the unit to maintain the filter. Premium High Vacuum Pump Oil, Quart Bottle (case of 12 bottles), Premium High Vacuum Pump Oil, Gallon Bottle (case of 4 bottles), Replacement Pump Module for 15600 Vacuum Pump, Installation Instructions (Document #116700), Replacement Dye Cartridges, 1/2 oz.