Flux-Fluid is applied on a specially designed pad made of the finest PE fibers. We don't have a lot of rules on audionirvana but we do have one request: please play nice! Put one probe inside the left output and the other on the outside. You can get a USB microscope for much less! Yeah! My system is designed in a way that my phono stage is permanently patched directly into my AD/DA interface, and I have just recorded tracks 1-3 from the Test LP into my DAW to measure the output level of these test tones. additional fixing screws are not necessary, Set 2: - Complete Height 6,5 mm - 1 x 0,5 mm, 1 x 1,0 mm, 1 x 2,0 mm, 1 x 3,0 mm. material: Lead wire: Silk wrapped OFC litz wire. For example, left channel spikes at 27on the fozgometer and then climbs up to close to 30, and right channel spikes at 30 and then descends down to 27. And while it can always be argued that there is no better accessory than a great record, here we have some very worthy (and some very wacky) alternatives. PLEASE CONTACT US FOR CURRENT SHIPPING INFORMATION BECAUSE OF THE CORONA SITUATION! https://www.analogplanet.com/content/fozgometer-owner-alert. For these reasons, accessories bring immediate and significant pleasure to this hi-fi game. Given the tools you have on hand buying a disc with the suitable tones and measuring directly should work for you. I think the obsession with azimuth may lead to more alignment errors and more distortion and stylus wear than one would care to admit. It is a small portable battery powered unit that is used in conjunction with a test record. While setting up my Garrard today, my friend Rick had brought round his Fozgometer and test l.p. ( amongst other essential tools!) You want optimally low distortion, I'm telling you. The results are super. by phillipivan 21 Aug 2015 11:17, Post With the DBP-10, you won't only achieve it, you'll have fun getting there. Measure the other side and adjust the azimuth until the higher figures are roughly equal in both channels. I used the Cardas Frequency Sweep test record. Macedon. Great minds think alike. https://www.superbestaudiofriends.org/index.php?threads/cartridge-alignment-setting-azimuth-with-a-p https://www.wallyanalog.com/wallyreference. Actually, the further the silvered surface is from where the stylus sits, the more apparent any deviation from level will be. I'll have to find another now. I'm not sure why you say that. In this situation, what should I base the reading on? The Fozgometer is an Azimuth Range Finder for adjusting cartridges in turntables. What do you use to measure / set azimuth of your cartridges and / or styli? Dont take my question as being combative, Im just curious if the Fozgometer has any unique qualities that lend it to being better or easier to use for the task. online shop | ANALOGUE PRODUCTIONS TEST LP - Recommended for use with the Musical Surroundings Fozgometer. My problem with it is the price. I searched this thread for references to tip zenith and came up empty. records are fat in the middle and the edge - therefore they bow across the surface. Do you think static might be the cause of the fluctuation? Both methods align the coils with the record not the stylus. When testing the feed from the tonearm cable, and along with the 'Analogue Production Ultimate Analogue Test LP', I am noticing an increase & decrease in either amplitude or signal metering on the fozgometer specifically on track 2 & 3 which are the azimuth adjustment tracks. Founded in 2010 Whats Best Forum invites intelligent and courteous people of all interests and backgrounds to describe and discuss the best of everything. Indeed, the race for "Accessory of the Year" is always one of the most entertaining because it involves such a diverse cast of characters. Accessories: GLSS VINYL CLEANER WET FILTER: When in operation the machine permanently filters the cleaning fluid. By the way, I agree that there is no need for a Foz if you have an oscilloscope and know how to use it (which many dont). When the cartridge is parallel to the grooves at these points then the distortion is optimally low across the recorded area of a modern LP record.". DELTA DEVICE Turntable Platter COVER DISC of PLEXIGLAS of a very fine and well known cartridge that had >3db channel imbalance and his comment back to me was: "that's what the balance control is for" and to some degree, he has a point. For my purposes, telling people to use a mono recording (which most are not set up for) can be rather confusing. Counterweight of tungsten metal Available color variations: silver Diameter: 34 mm Thickness: 12mm Weight: 120 g, Set 1: - Complete Height 3,5 mm - 1 x 0,5 mm, 1 x 1,0 mm, 1 x 2,0 mm. I have used both AM and Feickert's Adust + for azimuth, but now only use the SmarTractor and Fozgometer. by ripblade 22 Aug 2015 17:14, Post Audyssey Sub Equalizer ($799; reviewed by Kal Rubinson, Vol.33 No.1 review) To do this, you need a suitable test LP that has bands with signal only in one and then only in the other channel. I assume you're referring to meter readings all over the place. All in one 2mm, 4mm, 6mm and 8mm height adjustment spacer for Rega 3 point tonearms. precision-machined very precise parallelism and 90 angle. After all is said and done, it is not really a bad idea to set the cartridge visually typically using a mirror so that the cantilever is at a 90 degree angle to the surface of an LP. The record adaptor has been designed to be used with your 45rpm records that no longer have the centres, enabling you to play your old favourites. AC readings remain relatively consistent for me when I replay the test tracks. I use the Foz just to make sure my set-up's are in the zone (as a retailer, I have done a lot of set-ups). An alignment protractor is used to find the correct distance from stylus tip to tonearm pivot. The above methods may result in the best sound but I prefer the least record wear so I use the mirror method lewm referred to above. Micro Seiki SX-8000 table with flywheel, SME 3012R arm, SME 312S arm, Lyra Etna SL and Dynavector XV-1S cartridges, ARC Ref 3 phono stage, Otari MX-55 tape deck, Ampex 350 repros, Roon Nucleus Plus server, PS Audio DSJ DAC, ARC Ref 6 pre, ARC Ref 75 amp, JBL 4345 speakers, and Def Tech Ref subs. Bach: Six Suites for Unaccompanied Cello. From beginners to life-long hobbyists to industry professionals, we enjoy learning about new things and meeting new people, and participating in spirited debates. The new V2 continues the tradition of Musical Surroundings providing the best of everything analog since 1991. The SCA has a scope output, but if you have no scope, it has a dB meter built onto the faceplate. It should be set by ear or by use of a method such as test tones (a la fozgometer) or a test disc such as the AnalogMagik disc I prefer. Neither scalar-field generation nor grime-free records posed a real threat to this year's winner, however. What is the condition of the 9 volt battery, if you are in doubt replace it. DELTA DEVICE ACRYLIC TURNTABLE MAT Double-Sided GLSS VINYL CLEANER spare-parts-accessories: 180g Vinyl Gatefold LP | HIFI reseller TIZO ACRYL, The Watson's Record Cleaning Machine does just that, makes it easy, without making it expensive! I find by ear to be very easy. precision-machined very precise parallelism 0,02mm. I have found that minimizing crosstalk with a proper record gives a much more precise result than just equating the maximal value. is available in thickness 3mm. Counter Weight, Spacer), delivery in NON-EU countries is without VAT tax 19%, available | Can be shipped within 5-7 days, (colour: gray, option: without 7"-Single-Kit), incl. Near Mt. When I adjust by ear I get the image centered first. - Powered by, Analogue Productions -The Ultimate Analogue Test LP, Clearaudio Music-Pickup Test Record =Audiophile 180g LP=, Milty -Zerostat 3 = Anti-static Generator=, Clearaudio Weight Watcher Touch (Digital Cartridge Stylus Pressure Gauge ), Pro-Ject Measure s2- Digital Tracking Force Gauge. I second the use of the Foz and its accompanying test record. You simply cannot get a usable laptop for $150. I couldnt imagine not having at least one good oscilloscope. Where else in this event would you find a $79 record-washing system made of plastic (the fantastic Spin Clean) or a $2500 "scalar field generator" (the fascinating Quantum RT Qx4)? First thing. This DELTA DEVICE Tuning Support Platter The measurement can be repeated at the same pointafter azimuth adjustmentto further fine tune the exact same value received in both channels. I am afflicted with diminished eyesight, so aligning the azimuth of the stylus by eye is not practical. Our publication is supported by its audience. I used the 9V battery that was included with the unit in the initial calibration and azimuth adjustment. outside 33 & inside 45 rpm 50Hz. Physically it is the phase of the x-over signal that is the measurement signal not the level. THANK YOU! Lead wire: Silk wrapped silver wire. for high-quality and expensive cables Counterweight of compacted VA steel Suitable for RP3, RP6 and RP8 tonearm not included (color: silver) Diameter: 38 mm Weight: 100 g. The AT-LH13/OCC has an adjustable overhang and adjustable azimuth, as well as internal headhsell threads to avoid the use of nuts when fitting cartridges. Hey Rob, You blew my cover. The most accurate way is an oscilloscope. So what are your opinions in summary as to which is of more importance? When money's tight and we feel that pull to upgrade but can't afford a new source component or loudspeaker, we satisfy our longings with accessories. To start it helps to set a zero reference and go from there. What is the Best Tool to Measure Cartridge Azimuth? The reason I calibrated the unit is because, well I could. So, play test LP with (usually) 1kHz test tone in one channel only, set the signal appearing in the driven channel to 0 dB, and measure dB of output in the opposite channel, shown on the meter as a negative number of dB. I've always done it by sight and ear but there are better methods and devices like the fozgometer. ( without label recess !!! You still do need the test LP with 1kHz signal in one channel only. DETLA DEVICE PLEXIGLAS CABLE-HOLDER SET SIX-PIECE This makes it even harder to gauge an established reading for either left or right channel. Incorrect azimuth tends to splay sounds horizontally, making instruments and voices larger (spread wider) than they will be when azimuth is correct. I should think a USB microscope would work fabulously well. Prior to the Fozgometer, one had to eyeball or use an oscilloscope, AC voltmeter, or computer program, methods that can be complex and time-consuming. If by ear is not easy then by all means get a tool to help! www.acoustical-systems.com. And these results still don't explain why the Fozgometer meter increases or decreases during playback so significantly if there is only a -1 dB variation in output level. Since master sensei Jenkins hasn't weighed in yet, and at the risk of being schooled by him I found the Foz to be totally superfluous if you already own a good multi-meter like the FLUKE. To start viewing messages,
I recently picked up a Musical Surrounding Fozgometer for Azimuth correction. Paradigm Perfect Bass Kit PBK-1 ($299; reviewed by Kal Rubinson, Vol.33 No.1 review) Original JELCO JL- 45 Tonearm LiftCUEING DEVICE (made in Japan). 300mm material: Andyr, I work in Melbourne, but I live somewhere much nicer! You are using an out of date browser. The Clean it carbon fibre stylus cleaning brush is suitable for daily cleaning of the stylus Built-in safety features prevent fluid being sucked into the vaccum motor and the turntable motor overheating. Just a further suggestion. online shop | Atr Audio Trade ESTHER OFARIM - Esther LP 180g | Mastercut Recording (ATR 001) - 180g Vinyl Gatefold LP | HIFI reseller TIZO ACRYL, online shop | WATSONS RCM 230V Record Cleaning Machine - The Watson's Record Cleaning Machine does just that, makes it easy, without making it expensive! ( you can get the proper mirror from a camera repair). Quantum RT Qx4 "scalar field generator" ($2499.99; reviewed by Art Dudley, Vol.32 No.12, Vol.33 No.1 review) I use the Adjust+ and while it needs a bit of mastering--even an idiot like Moi. by phillipivan 21 Aug 2015 08:57, Post To achieve the best performance, your phono cartridges azimuth must be calibrated. On the surface, the two have nothing in commonuntil we remember that both fulfill those audiophilic needs of immediate gratification and unbridled fun. I could very well be missing that last 1% of performance improvement that could be had but I'm satisfied with what I get now. I am not suggesting that this is a substitute for the Foz or other software based solutions but a starting point to figure out whether you have a problem to begin with. Although, by definition, accessories are ancillary or superficial parts of our audio lives, they may also be considered gateways to periods of enhanced enjoyment and as invaluable sources of pure fun. For a better experience, please enable JavaScript in your browser before proceeding. The SmarTractor is one of the most accurate protractors available - Analog Magik even suggests using it for a good initial setting before starting the tests in its module. there's an acceptable margin as someone else said (<3db). Feeling the urge to produce some slight change in a system's soundreal or imagined, good or bad, it sometimes makes no differencewe turn to accessories. Taking just maximum/minimum peak values and dividing them by 2 won't cut itover a time pragmatic relationship. Custom made high quality Regaturntabledrive belt. It wasn't until I read the comments on Michael Fremer's article that you linked regarding the 9V battery, and fortunately my mulitmeter displayed a reading of around 7V. I have had no problem with my Fozgometer I find it very handy and reliable. It may not display this or other websites correctly. | HIFI reseller TIZO ACRYL, online shop | Atr Audio Trade JAZZ AT THE PAWNSHOP Double LP | (PROP 7778/9) - Arne Domnrus 180g Vinyl Gatefold LP | HIFI reseller TIZO ACRYL, online shop | WATSONS Record Cleaning Fluid 60ml Concentrated Good for 900ml | HIFI reseller TIZO ACRYL. This page was generated at 12:18 PM. I find this odd as I would think tip zenith would have a more direct impact on the channel phase relationships than azimuth since the tip zenith scans the groove directly, whereas azimuth is more a function of the physical location of the coils in relation to the surface of the record. Arrggghhh. There are lot of previous threads about this. The milled lines are more advantageous than laser engraving, because they are easier to see by light irradiation. Play the two test tones and note the higher measurements (about 220 for me) and ignore the lower figures (noise and cross talk). Let us know about your favorite speakers, amplifiers, turntables, DACs and music. 300mm It takes awhile, more than 4 tries You must log in or register to reply here. If your azimuth setting is off the vocal image will not be dead centre but will cling to one speaker etc. The reading should be across the entirety of afull spectrum plot where the true average value can be established. here and share your audio and music experiences with our community of high-end audio enthusiasts! by TA 22 Aug 2015 21:47, Post simply select the forum that you want to visit from the selection below. The next thing is that you are following the instructions, plugging your tone arm leads directly into the Fozgometer and the test disc is flat. If one is crazed enough to want to set azimuth electrically, you can use a Fozgometer for sure or any of a few other methods for minimizing crosstalk. Allows the REGA turntable with closed dust cover when a VTA correction of more than 3 mm is necessary. What's your favorite method for adjusting azimuth of a phono cartridge? Correct azimuth alignment assures the highest channel separation and best channel balance, providing outstanding sound and imaging from your stereo record collection. TONARMLIFTML50 1/2" 12,8mm after JELCO JL-45 specifications by MAGAUDIO Made in Germany. Introducing our Fozgometer V2 azimuth range meter, the unique tool to optimize your phono cartridge azimuth for the best sound from your HiFi system. The initial spike, the average, or the final reading before tone ends? The cartridge alignment tool is made of PLEXIGLAS (Acryl) transparent - You need a voltmeter and a test record with a band that plays a 1kHz tone into the Left channel and a band playing the tone into the Right channel. Spin Clean Record Wash System ($79.99; reviewed by Michael Fremer, Vol.33 No.2). for high-quality and expensive cable for example speaker cable, power cable Small counterweight of tungsten metal Available color variations: silver Diameter: 34 mm Thickness: 34mm Weight: 100 g, online shop | van den Hul The Mainsstream 7 socket block - available lengths: 1,5m 2,0m und 2,5m | HIFI reseller TIZO ACRYL. Phono cartridge azimuth is a key parameter for getting the best stereo imaging and sound staging. The world's largest high-end audio community. GLSS VINYL CLEANER spare-parts-accessories: SET 2 x Cleaning Fluid (20ml), 1 x wet filter, 4 x micro-fibre cleaning barrels, NEW : original ortofon | Reference RED 1,0m -, Cable capacity: 190pF/m Cable length: 1.0 m Terminal type: RCA 2 pieces per set, Accessories: LP cleaning machine GLSS VINYL CLEANER SET WIPERS (2 pieces/set), DOS-10399 Jelco Style headshell | SME bayonet connection + azimuth adjustment | approx. Or those accessories and tweaks that bring out the best in your system! and if a channel imbalance exist, it could be the generator, coils etc. Once you use it, you'll wish you'd had it earlier; this machine is a real godsend! Ok, I re read your post, I'm presently working my way through a bottle of wine so I was a little hasty with my reply! IMO, best practices should always put styli at 90 degrees to the LP surface (viewed head on with your Dinolite) regardless of what yer Foz or multi-meter is telling you. Have you tried cleaning the test record? Calibration was performed visually and there were no real issues with this phase. (note: leave the probes in the same channel and switch the tonearm interconnects, to eliminate any phono preamp channel variations). We would love to have you register
Set 3: - Complete Height 2,0 mm - 1 x 2,0 mm Then I adjust by ear. Crosstalk, Seperation, or Phase??? New VINYL CLEANER PRO X incl. That gives you a stylus aligned to the groove and you can't beat the price. Take a mono record, preferably female vocal with minimal accompaniment and play it with a stereo cart. The Fozgometer V2 is an Azimuth Range Finder for adjusting cartridges in turntables. In fact I read this article while I was waiting for the Fozgometer to be shipped, so I was well prepared. One should also pay attention to how the various parameters interact. Initially I used an oscope for setup but, now as the cartridge is about broke in 80 hours. DOS Headshell Jelco Style (HS25) Azimut Alignment with Headshellcable ca.14.46g. I'm quite happy with the old method of using the lead of a mechanical pencil and a machinist's steel rule graduated in 64ths to set azimuth, but I've never looked at confirming it by measuring output for the reasons stated above. there's an acceptable margin as someone else said (<3db). These are the results based on the metering (persistence range & normal peak range): Track 1: 1KHz reference tone - lateral in phase (mono), Track 2: 1KHz reference level, left channel only, Metering on average at -23 dBFS, dips down to -24 dBFS and then rises again to -23 dBFS midway through playback, some peaks on surface noise, Track 3:1KHz reference level, right channel only, Metering on average at -23 dBFS,dips down to -24 dBFS and then rises again to -23 dBFS midway through playback, some peaks on surface noise, The beginning of the tone on track 2 & 3 peaks at -23 dBFS, so at least that is consistent but I cannot explain the fluctuation or dip and rise in level during playback. diameter: